Droop Control in DC Grids using the Universal Four Leg as Laboratory Setup

AIUE Proceedings of the 2nd Energy and Human Habitat Conference 2021

5 Pages Posted: 9 Aug 2021

See all articles by Alexander Spaans

Alexander Spaans

The Hague University of Applied Sciences

Diëgo Zuidervliet

The Hague University of Applied Sciences

Peter van Duijsen

The Hague University of Applied Sciences

Date Written: July 26, 2021

Abstract

Droop control is used for power management in DC grids. Based on the level of the DC grid
voltage, the amount of power regulated to or from the appliance is regulated such, that power
management is possible. The Universal 4 Leg is a laboratory setup for studying the functionality of
a grid manager for power management. It has four independent outputs that can be regulated with
pulse width modulation to control the power flow between the DC grid and for example, a
rechargeable battery, solar panel or any passive load like lighting or heating

Keywords: DC Grid, Droop Control, Power Management, U4L, Caspoc

Suggested Citation

Spaans, Alexander and Zuidervliet, Diëgo and van Duijsen, Peter, Droop Control in DC Grids using the Universal Four Leg as Laboratory Setup (July 26, 2021). AIUE Proceedings of the 2nd Energy and Human Habitat Conference 2021, Available at SSRN: https://ssrn.com/abstract=3899714 or http://dx.doi.org/10.2139/ssrn.3899714

Alexander Spaans

The Hague University of Applied Sciences ( email )

Johana Westerdijkplein 75
The Hague, Zuid Holland 2521 EN
Netherlands

Diëgo Zuidervliet

The Hague University of Applied Sciences ( email )

Johana Westerdijkplein 75
The Hague, Zuid Holland 2521 EN
Netherlands

Peter Van Duijsen (Contact Author)

The Hague University of Applied Sciences ( email )

Johana Westerdijkplein 75
The Hague, Zuid Holland 2521 EN
Netherlands

Do you have negative results from your research you’d like to share?

Paper statistics

Downloads
58
Abstract Views
406
Rank
659,613
PlumX Metrics