Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an Inclined Circular Duct

Volume. 7, Issue. 9, September - 2018, IJERT

7 Pages Posted: 22 Oct 2018

See all articles by Bishal Bhandari

Bishal Bhandari

Visvesvaraya Technological University

Madhav Rijal

Visvesvaraya Technological University (VTU)

Date Written: September 22, 2018

Abstract

Circular duct has various applications - pipelines, HVAC, and refrigeration - as it can withstand more pressure drop than non-circular duct. Generally, fluids are forced through the pipes for various purposes. So, Pipes are generally required to be installed at various positions in order to minimize or maximize heat loss, regulate the flow and for the proper utilization of space to meet the design considerations. When fluids are forced through pipes, Heat transfer follows forced convection and the convective heat transfer coefficient plays pivotal role in the design considerations. Hence, it is must to understand the influence of factors such as inclination of pipe, velocity of fluid, and temperature gradient on convective heat transfer coefficient. Literature survey showed little research on effect of those factors in convective heat transfer coefficient. The main purpose of this work is to find out the nature of convective heat transfer coefficient when the air is forced through the copper pipe at different inclination and velocity at constant heat input. Different temperature at various points and the manometer reading were noted and were used to calculate Reynolds number, Prandtl number, and Nusselts number to find out convective heat transfer coefficient. The result obtained was plotted to observe the nature of heat transfer coefficient. The graph showed that heat transfer coefficient rises to its peak at 900 inclination of the duct for velocity of 12 m/s and falls to minimum value at 300 inclination of the duct for velocity of 8.38 m/s. It is also found that heat transfer coefficient is linearly dependent on velocity and is also influenced by inclination of the duct.

Keywords: Fluids, Convection, Convective Heat Transfer Coefficient, Reynolds Number, Prandtl Number, Nusselts Number

Suggested Citation

Bhandari, Bishal and Rijal, Madhav, Evaluation of Convective Heat Transfer Coefficient of Air Flowing Through an Inclined Circular Duct (September 22, 2018). Volume. 7, Issue. 9, September - 2018, IJERT . Available at SSRN: https://ssrn.com/abstract=3256827 or http://dx.doi.org/10.2139/ssrn.3256827

Bishal Bhandari (Contact Author)

Visvesvaraya Technological University ( email )

Karnataka State
India

Madhav Rijal

Visvesvaraya Technological University (VTU) ( email )

Jnanasangama Machhe
Khanapur Road
Belgaum, Karnataka 590014
India

Register to save articles to
your library

Register

Paper statistics

Downloads
12
Abstract Views
98
PlumX Metrics