Flexible Multielectrode Arrays Based Electrochemical Aptasensor for Glycated Human Serum Albumin Detection

21 Pages Posted: 28 Jan 2023

See all articles by Lei Zhou

Lei Zhou

Research Centre Jülich

Gabriela Figueroa-Miranda

Research Centre Jülich

Song Chen

Research Centre Jülich

Marc Neis

Research Centre Jülich

Ziheng Hu

Research Centre Jülich

Ruifeng Zhu

Research Centre Jülich

Yaqi Li

Research Centre Jülich

Michael Prömpers

Research Centre Jülich

Andreas Offenhäusser

Research Centre Jülich

Dirk Mayer

Research Centre Jülich

Abstract

Assessment tests for glycemic control of patients with diabetes mellitus commonly use blood glucose and glycated hemoglobin A1C (HbA1C) levels for estimating acute and long-term glycemia, respectively. Diabetes diet, as well as treatment, are adapted accordingly and also the risk of diabetic complications can be estimated. Glycated human serum albumin (GHSA) has been proposed as an alternative to HbA1C since it possesses a four times shorter lifespan and its blood concentration is not affected by hemic diseases. Here, an electrochemical aptasensor is proposed for the simultaneous detection of human serum albumin (HSA) and GHSA utilizing flexible multielectrode arrays. The polymer chip carried two individual sets of gold electrodes, which are separately modified by the corresponding aptamers. The dual-target aptasensors possessed detection limits as low as 13 nM and 25 nM for HSA and GHSA, respectively, together with detection ranges lasting from 40 nM to 10 µM. Moreover, our aptasensor quantified selectively its target in diluted full-blood samples. This low-cost plastic aptasensor facilitates the quantitative determination of HSA and GHSA ratios by analyzing the current signals from several redundant electrodes, which permits a reliable and affordable estimation of long-term glycemia at point-of-care or home.

Note:
Funding Declaration: L. Zhou gratefully acknowledges financial support from the China Scholarship Council (No. 201708320255).
Conflict of Interest: There are no conflict of interest.

Keywords: Keywords: Glycemic control, Flexible multielectrode arrays, Dual-target analysis, Glycated albumin, Electrochemical aptasensor, Blood samples

Suggested Citation

Zhou, Lei and Figueroa-Miranda, Gabriela and Chen, Song and Neis, Marc and Hu, Ziheng and Zhu, Ruifeng and Li, Yaqi and Prömpers, Michael and Offenhäusser, Andreas and Mayer, Dirk, Flexible Multielectrode Arrays Based Electrochemical Aptasensor for Glycated Human Serum Albumin Detection. Available at SSRN: https://ssrn.com/abstract=4328224 or http://dx.doi.org/10.2139/ssrn.4328224

Lei Zhou

Research Centre Jülich ( email )

Germany

Gabriela Figueroa-Miranda

Research Centre Jülich ( email )

Germany

Song Chen

Research Centre Jülich ( email )

Germany

Marc Neis

Research Centre Jülich ( email )

Germany

Ziheng Hu

Research Centre Jülich ( email )

Germany

Ruifeng Zhu

Research Centre Jülich ( email )

Germany

Yaqi Li

Research Centre Jülich ( email )

Germany

Michael Prömpers

Research Centre Jülich ( email )

Germany

Andreas Offenhäusser

Research Centre Jülich ( email )

Dirk Mayer (Contact Author)

Research Centre Jülich ( email )

Do you have a job opening that you would like to promote on SSRN?

Paper statistics

Downloads
72
Abstract Views
287
Rank
621,927
PlumX Metrics