Abnormal Energy Consumption Detection Using Ensemble Model for Water Chilling Unit on Hvac System

15 Pages Posted: 20 Apr 2023

See all articles by Luyao CHEN

Luyao CHEN

Huazhong University of Science and Technology

Zheng Liu

Huazhong University of Science and Technology

Huanxin Chen

affiliation not provided to SSRN

Hengda Cheng

Huazhong University of Science and Technology

Abstract

To address the problem that the energy consumption of chiller is affected by multiple factors and lacking of abnormal detection model which can be used for energy consumption of chillers, an integrated model based on partitioning around medoids (PAM), support vector classification (SVC) and 3-σ rules is proposed in this study. In the detection of abnormal energy consumption of the chillers, the observed data of a HVAC system from Hubei province, China are used to develop and evaluate the integrated model. PAM is applied to divide consumption patterns of the historical data. SVC is applied to recognize consumption patterns of the testing data. 3-σ rules are used for abnormal detection. The results show that PAM divide the energy consumption into four patterns, SVC multi-classifier can effectively recognize energy consumption patterns with an accuracy reaches 98.29%. Compared with the popular model, the integrated learning model applied for the detection of abnormal energy consumption reaches a twice as high as the 40% detection success rate of the 3-σ rules. Moreover, the patterns recognition component can be used to understand the people’s energy consumption behavior and the anomaly detection component can be used to regulate the energy usage.Keywordsabnormal chiller energy consumption detection; partitioning around medoids; support vector classification; patterns division; patterns recognition

Keywords: abnormal chiller energy consumption detection, partitioning around medoids, support vector classification, patterns division, patterns recognition

Suggested Citation

CHEN, Luyao and Liu, Zheng and Chen, Huanxin and Cheng, Hengda, Abnormal Energy Consumption Detection Using Ensemble Model for Water Chilling Unit on Hvac System. Available at SSRN: https://ssrn.com/abstract=4424462 or http://dx.doi.org/10.2139/ssrn.4424462

Luyao CHEN

Huazhong University of Science and Technology ( email )

1037 Luoyu Rd
Wuhan, 430074
China

Zheng Liu

Huazhong University of Science and Technology ( email )

1037 Luoyu Rd
Wuhan, 430074
China

Huanxin Chen (Contact Author)

affiliation not provided to SSRN ( email )

No Address Available

Hengda Cheng

Huazhong University of Science and Technology ( email )

1037 Luoyu Rd
Wuhan, 430074
China

Do you have a job opening that you would like to promote on SSRN?

Paper statistics

Downloads
28
Abstract Views
130
PlumX Metrics