Real-Time Lead Detection Device Based on Nanomaterials Modified Microwave-Microfluidic Sensor

11 Pages Posted: 19 Jun 2023

See all articles by Weijia Cui

Weijia Cui

University of Waterloo

Zhe Ren

Dalian Maritime University

Zahra Abbasi

University of Calgary

Yongxin Song

Dalian Maritime University - College of Marine Engineering

Carolyn Ren

University of Waterloo

Abstract

Lead contamination in drinking water has become an increasingly serious global risk because a small concentration of lead can cause serious health problems, particularly for children. It is critical to frequently monitor lead concentration in drinking water, which can be challenging when using traditional centralized systems. In this study, we present an inexpensive, portable detection system for point-of-care (POC) monitoring of lead concentration in drinking water. The sensing mechanism is based on the interaction between the water sample flowing through a microchannel and a planar microwave resonator-based sensor that is integrated with the microfluidic chip. The microwave sensor has a double-T structure with a gap in between through which the microchannel is aligned and can be coated with gold nanoparticles to enhance its sensing performance. For proof-of-concept, the sample under test (SUT) was a small volume of deionized (DI) water or tap water spiked with lead ions at different concentrations. Results show that the gold nanoparticle-coated microwave sensor presents a much higher sensitivity than bare sensors with a detectable frequency shift of 5 MHz for a Pb2+ solution with a concentration of 1 ppb. The success of the system for testing lead ions in typical tap water which contains many different mineral ions confirms its real-world application. To highlight the potential for POC applications, a low-cost, portable vector network analyzer is used to capture the frequency shift of the sensor. The developed method offers a promising approach for POC monitoring of lead contamination in drinking water impactful for environmental and public health protection.

Keywords: Lead, Drinking water, Microwave sensor, Microfluidics, Gold nanoparticles

Suggested Citation

Cui, Weijia and Ren, Zhe and Abbasi, Zahra and Song, Yongxin and Ren, Carolyn, Real-Time Lead Detection Device Based on Nanomaterials Modified Microwave-Microfluidic Sensor. Available at SSRN: https://ssrn.com/abstract=4483935 or http://dx.doi.org/10.2139/ssrn.4483935

Weijia Cui

University of Waterloo ( email )

Waterloo, N2L 3G1
Canada

Zhe Ren

Dalian Maritime University ( email )

1 Linghai Road
Dalian, 116026
China

Zahra Abbasi

University of Calgary ( email )

University Drive
Calgary, T2N 1N4
Canada

Yongxin Song

Dalian Maritime University - College of Marine Engineering ( email )

Carolyn Ren (Contact Author)

University of Waterloo ( email )

Waterloo, N2L 3G1
Canada

Do you have a job opening that you would like to promote on SSRN?

Paper statistics

Downloads
21
Abstract Views
104
PlumX Metrics