Performance of 4h-Sic Radiation Detector after High Flux Proton and Fe13+ Heavy Ion Beam Irradiation

15 Pages Posted: 12 Jan 2024

See all articles by Chunlin Zhang

Chunlin Zhang

Lanzhou Jiaotong University

Kai Yang

Lanzhou Jiaotong University

Haixia Li

affiliation not provided to SSRN

Ronghua Li

affiliation not provided to SSRN

Zhankui Li

affiliation not provided to SSRN

Tongmin Zhang

Czech Technical University

Ziwei Lu

affiliation not provided to SSRN

Xiuhua Wang

affiliation not provided to SSRN

Fengqiong Liu

affiliation not provided to SSRN

Cuihong Chen

affiliation not provided to SSRN

Lei Zhang

Lanzhou Jiaotong University

Qun Liu

Lanzhou University

Gaigai Wu

Lanzhou Jiaotong University

Abstract

A batch of Schottky diode 4H-SiC detectors was fabricated by using Ni/ Au electrodes, which were irradiated by Fe13+ heavy ion beam current with a flux of 1×1013 n/cm2 to 4.35×1014 n/cm2 in a stepwise increment, the forward and reverse I-V characteristics before and after irradiation as well as the energy resolution of α particles produced by 241Am source were tested and compared. The test results show that the reverse leakage current of the 4H-SiC detector that we made under the radiation of Fe13+ heavy ion beam increases gradually with the increase of the irradiation flux, Schottky Barrier Height decreases continuously and the ideal factor gradually increases. When the flux is 4×1013 n/cm2, it has risen to 9 μA, but the detector still has an energy resolution of 2.63%. When the flux of Fe13+ heavy ion beam is increased to 8×1013 n/cm2, the very obvious degradation phenomenon appeares, the Charge Collection Efficiency(CCE) is reduced from 100% to 66.08%, the energy resolution is changed from 1.6% to 4.33%. When flux is increased to 1.4×1014 n/cm2, and the detector’s performance has degraded seriously, in which the energy resolution is decreased from 1.76% to 9.54%, meanwhile the CCE is reduced from 100% to 64.84%, but it can still be used. As the beam flux reaches 2×1014 n/cm2, the detector has been completely damaged. At the same time, the ability of the detector to resist mixed ion beam irradiation was tested. The 4H-SiC detector still has an energy resolution of 2.51% after receiving a dose of irradiation, concluding with 1×1017 n/cm2 protons and 2×1013 n/cm2 Fe13+ heavy ion beams.

Keywords: 4H-SiC, Radiation detector, Fe13+ Heavy Ion Beam, Energy resolution

Suggested Citation

Zhang, Chunlin and Yang, Kai and Li, Haixia and Li, Ronghua and Li, Zhankui and Zhang, Tongmin and Lu, Ziwei and Wang, Xiuhua and Liu, Fengqiong and Chen, Cuihong and Zhang, Lei and Liu, Qun and Wu, Gaigai, Performance of 4h-Sic Radiation Detector after High Flux Proton and Fe13+ Heavy Ion Beam Irradiation. Available at SSRN: https://ssrn.com/abstract=4692379 or http://dx.doi.org/10.2139/ssrn.4692379

Chunlin Zhang (Contact Author)

Lanzhou Jiaotong University ( email )

China

Kai Yang

Lanzhou Jiaotong University ( email )

China

Haixia Li

affiliation not provided to SSRN ( email )

No Address Available

Ronghua Li

affiliation not provided to SSRN ( email )

No Address Available

Zhankui Li

affiliation not provided to SSRN ( email )

No Address Available

Tongmin Zhang

Czech Technical University ( email )

Ziwei Lu

affiliation not provided to SSRN ( email )

No Address Available

Xiuhua Wang

affiliation not provided to SSRN ( email )

No Address Available

Fengqiong Liu

affiliation not provided to SSRN ( email )

No Address Available

Cuihong Chen

affiliation not provided to SSRN ( email )

No Address Available

Lei Zhang

Lanzhou Jiaotong University ( email )

China

Qun Liu

Lanzhou University ( email )

222 Tianshui South Road
Chengguan
Lanzhou, 730000
China

Gaigai Wu

Lanzhou Jiaotong University ( email )

China

Do you have a job opening that you would like to promote on SSRN?

Paper statistics

Downloads
10
Abstract Views
132
PlumX Metrics