A Mechanical Biosensor Based on Magnetic-Mediated Sensitization for 5-Ht Detection

19 Pages Posted: 29 Apr 2024

See all articles by Dong Zhao

Dong Zhao

Taiyuan University of Technology

Penglong Yao

Taiyuan University of Technology

Zhaosheng Yan

Taiyuan University of Technology

aoqun Jian

Taiyuan University of Technology

Jinsuo Bai

Taiyuan University of Technology

Haoyu Wang

Taiyuan University of Technology

Xing Guo

Taiyuan University of Technology

Shengbo Sang

Taiyuan University of Technology - Shanxi Key Laboratory of Micro Nano Sensors & Artificial Intelligence Perception

Chuangang Zhou

Taiyuan University of Technology

Xiushan Dong

Shanxi Bethune Hospital - Shanxi Academy of Medical Sciences

Abstract

The real-time detection of neurotransmitters had attracted more attention due to the potential to provide vital information for pathology research, disease diagnosis, and clinical efficacy evaluation. Here, a magnetic-mediated biosensor was developed to improve sensitivity for detection of serotonin (5-HT). The PDMS membrane doped with magnetic particles serves as a conversion element, enhancing the deformation of the thin film caused by surface stress under the action of a magnetic field and amplifying the resistance response signal of the biosensor. The 5-HT detection associated with neurotransmitter diseases serve as a proof of concept revealing the magnetic sensitization. The detection limit of the 5-HT was decreased to 3.21 nM in the linear range of 5-500 nM, which was lower than that of the biosensor without magnetic field. The clinical 5-HT samples were also been accurately detected, indicating a positive application potential of the as-prepared magnetic-mediated biosensor. All these results reveal the high sensitivity and practicality of the as-prepared magnetic-mediated biosensor and provide a new method for neurotransmitter diseases diagnosis.

Keywords: magnetic mediation, sensitization, 5-HT detection, biosensor

Suggested Citation

Zhao, Dong and Yao, Penglong and Yan, Zhaosheng and Jian, aoqun and Bai, Jinsuo and Wang, Haoyu and Guo, Xing and Sang, Shengbo and Zhou, Chuangang and Dong, Xiushan, A Mechanical Biosensor Based on Magnetic-Mediated Sensitization for 5-Ht Detection. Available at SSRN: https://ssrn.com/abstract=4804568 or http://dx.doi.org/10.2139/ssrn.4804568

Dong Zhao (Contact Author)

Taiyuan University of Technology ( email )

No.79 West Yingze Street
Taiyuan
China

Penglong Yao

Taiyuan University of Technology ( email )

No.79 West Yingze Street
Taiyuan
China

Zhaosheng Yan

Taiyuan University of Technology ( email )

No.79 West Yingze Street
Taiyuan
China

Aoqun Jian

Taiyuan University of Technology ( email )

No.79 West Yingze Street
Taiyuan
China

Jinsuo Bai

Taiyuan University of Technology ( email )

No.79 West Yingze Street
Taiyuan
China

Haoyu Wang

Taiyuan University of Technology ( email )

No.79 West Yingze Street
Taiyuan
China

Xing Guo

Taiyuan University of Technology ( email )

No.79 West Yingze Street
Taiyuan
China

Shengbo Sang

Taiyuan University of Technology - Shanxi Key Laboratory of Micro Nano Sensors & Artificial Intelligence Perception ( email )

Chuangang Zhou

Taiyuan University of Technology ( email )

No.79 West Yingze Street
Taiyuan
China

Xiushan Dong

Shanxi Bethune Hospital - Shanxi Academy of Medical Sciences ( email )

Do you have a job opening that you would like to promote on SSRN?

Paper statistics

Downloads
25
Abstract Views
249
PlumX Metrics