Thermal and Hygrothermal Analysis of Prefabricated Facades with Active Components for Minimal Invasive Renovations

34 Pages Posted: 25 Nov 2024

See all articles by William Monteleone

William Monteleone

University of Innsbruck

Riccardo Pinotti

Eurac Research

Fabian Ochs

University of Innsbruck

Georgios Dermentzis

University of Innsbruck

Abstract

To achieve a decarbonized building stock by 2050, the renovation rate must be significantly increased by means of cost-effective, minimally invasive, and scalable solutions. Prefabricated façades with integrated active components such as heat pump (HP) or mechanical ventilation with heat recovery (MVHR) offer a promising approach, particularly in multi-family buildings. These solutions enhance the building envelope performance and accelerate the replacement of fossil-based heating systems. However, there is limited understanding of how integrated components affect the heat transfer in prefabricated façades and influence interior wall surface temperatures. This work presents two case studies involving two types of façade-integrated HPs and a MVHR system. Both HPs were tested in a laboratory and the temperature and relative humidity around the equipment and within the façade were monitored. A thermal model was calibrated for both cases based on the measurements, focusing on the most critical thermal sections. In case study A with the exhaust-to-supply air HP, a significant thermal bridge was found between the window and the HP cavity, with heat fluxes reaching 50 W/m² and surface temperatures up to 2 K lower than the indoor air. In case study B with the façade-integrated outdoor unit of a mini-split domestic hot water HP, an overall heat transfer coefficient for the façade of 0.46 W/(m² K) was measured. The most critical area was between timber beams and the cavity, where a heat flux of 27.5 W/m² was observed and the surface temperature was about 1 K lower than the indoor air temperature. Recommendations are made for proper installation of façade-integrated equipment in prefabricated timber façades to guarantee uncritical long-term operation.

Keywords: Deep serial thermal renovation, Façade integration, Thermal Simulation, heat pump, Mechanical Ventilation with Heat Recovery.

Suggested Citation

Monteleone, William and Pinotti, Riccardo and Ochs, Fabian and Dermentzis, Georgios, Thermal and Hygrothermal Analysis of Prefabricated Facades with Active Components for Minimal Invasive Renovations. Available at SSRN: https://ssrn.com/abstract=5031450 or http://dx.doi.org/10.2139/ssrn.5031450

William Monteleone (Contact Author)

University of Innsbruck ( email )

Universitätsstraße 15
Innsbruck, 6020
Austria

Riccardo Pinotti

Eurac Research ( email )

Bolzano
Italy

Fabian Ochs

University of Innsbruck ( email )

Universitätsstraße 15
Innsbruck, 6020
Austria

Georgios Dermentzis

University of Innsbruck ( email )

Universitätsstraße 15
Innsbruck, 6020
Austria

Do you have a job opening that you would like to promote on SSRN?

Paper statistics

Downloads
15
Abstract Views
108
PlumX Metrics