Welding Defects With Radiographic Images

7 Pages Posted: 26 Feb 2025

Date Written: January 05, 2025

Abstract

In addition to producing high quality radiographs, the radiographer must also be skilled in radiographic interpretation. Interpretation of radiographs takes place in three basic steps: (1) detection, (2) interpretation, and (3) evaluation. All of these steps make use of the radiographer's visual acuity. Visual acuity is the ability to resolve a spatial pattern in an image. The ability of an individual to detect discontinuities in radiography is also affected by the lighting condition in the place of viewing, and the experience level for recognizing various features in the image. The following material was developed to help students develop an understanding of the types of defects found in weldments and how they appear in a radiograph.

Discontinuities are interruptions in the typical structure of a material. These interruptions may occur in the base metal, weld material or "heat affected" zones. Discontinuities, which do not meet the requirements of the codes or specifications used to invoke and control an inspection, are referred to as defects.

Cold lap is a condition where the weld filler metal does not properly fuse with the base metal or the previous weld pass material (interpass cold lap). The arc does not melt the base metal sufficiently and causes the slightly molten puddle to flow into the base material without bonding.

Keywords: Petroleum industry, welding, Radiograph Interpretation - Welds

Suggested Citation

Hadzihafizovic, Dzevad, Welding Defects With Radiographic Images (January 05, 2025). Available at SSRN: https://ssrn.com/abstract=5083295

Dzevad Hadzihafizovic (Contact Author)

University of Sarajevo ( email )

Obala Kulina bana 7
71000 Sarajevo
Bosnia and Herzegovina

HOME PAGE: http://akademskiimenik.ba/profil/1319

Do you have a job opening that you would like to promote on SSRN?

Paper statistics

Downloads
44
Abstract Views
100
PlumX Metrics